PELLET STOVES 7 PS45 CLASSIC 151211-24
NOTE: INSTALL VENT
AT CLEARANCES
SPECIFIED BY THE
VENT MANUFACTURER
Clearances to Combustibles
Clearances:
Front 48” (1.2m)
Side 6" (155mm)
Back 3” (76mm)
The center of the ue is 16-1/2” above the surface upon
which the stove rests.
IMPORTANT
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
• Minimum clearances speci ed may not allow for ease of
operation and maintenance (please take this in to account when
planning the installation). If installed to the minimum clearances,
removal of the appliance may be necessary for servicing.
• Recommended clearance zone from the front
of the appliance to combustibles is 4 feet minimum.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO
SCALE.
Alcove Installations
Minimum alcove height is 5 ft. (1.54 m), minimum width is 36
in. (92 cm) and maximum depth is 24 in. (61 cm).
Note, it is difficult to service the unit when installed
in a 36 in. alcove and may require the unit to be
removed for servicing. Please allow as much area
on either side of the unit as possible for ease of
service.
3”
6”
6”
24”
*See Vent Manufacturer’s
instructions
3”
6”
3”
3”
Fig# 3a Corner Install
Fig #3b Right Wall - Horizontal Vent
Fig #3c Right Wall - vertical vent
Fig #3d Alcove Installation