PELLET STOVES 3 PS45 CLASSIC 151211-24
Introduction
OPERATION: For proper and safe operation, the door and
ash drawer must be kept closed to prevent fume spillage when
the unit is in operation. The Auger will not operate when they
are open. Check all gaskets on the Door, Ash Pan and Hopper
lid and replace when necessary.
CAUTION: When operating during extreme weather, if the
unit exhibits dramatic changes in combustion stop using the
unit immediately.
CLEANING: There will be some build up of  y ash with
small amounts of creosote in the exhaust. This will vary due to
the ash content of the fuel used and the operation of the stove.
Inspect the venting periodically during the heating season to
determine if a creosote buildup has occured. If a signi cant
layer of creosote has accumulated,(3mm or more)it should be
removed to reduce the risk of a chimney  re. Venting should be
cleaned annually or every two tons of pellets used.
CAUTION: The appliance,  ue gas connector and the
chimney  ue require regular cleaning. Check them for blockage
prior to re-lighting after a prolonged shut down period.
ASHES: Disposed ashes should be placed in a metal
container with a tight  tting lid. The closed container of ashes
should be on a non-combustible surface, well away from all
combustible materials pending  nal disposal. If the ashes are
disposed of by burial in soil or otherwise locally dispensed, they
should be retained in the closed container until all cinders have
thoroughly cooled.
SOOT: Operation of the stove with insufficient combustion
air will result in the formation of soot and/or creosote which
will collect on the glass, the heat exchanger, the exhaust vent
system, and may stain the outside of the house. Frequently check
your stove and adjust as needed to ensure proper combustion.
See: “VENT/DAMPER SETTING”.
SMOKE DETECTORS - Since there are always several
potential sources of  re in any home, we recommend installing
smoke detectors. If your local code requires a smoke detector be
installed within the same room, you must follow the requirements
of your local code. Check with your local building/ re department
for requirements in your area.
THERMOSTAT: This stove can be operated manually or
with a low voltage wall thermostat. (see page 12)
IGNITION: This stove is equipped with an electric self igniter
system.
If you have any questions with regards to your stove or the
above-mentioned information, please contact your local dealer
for further clari cation and comments.
SAVE THIS INSTRUCTION MANUAL
FOR FUTURE REFERENCE
Speci cations
Rating Label Location::
The rating label is located on the inside of the Hopper Lid
Listing information
The Warmland PS45 Classic stove was safety tested by Intertek
Testing Services NA Ltd. and is listed to the following standards:
ASTM 1509-04, ULC 627S, UL 1482
Heating Speci cations:
• Max. feed rate is up to 5.2 pounds/hour or 45,000 BTU/hour
• Min. feed rate is 1.3 pounds/hour or 12,000 BTU/hour
*** Depending on fuel type and quality ***
Electrical:
• 120 volts, 60 Hz
• 700 Watts - Maximum.
• 300 Watts - Normal operating.
WARNING
This appliance is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and should be plugged directly into
a properly grounded three-prong, 120 volt, 60 Hz
receptacle. Do not cut or remove the grounding
prong from this plug. Do not route power cord
under or in front of appliance. The power supply
cord must be routed to avoid contact with any
of the hot or sharp exterior surface areas of the
stove.
The use of a surge protected power bar is recommended to
ensure the stoves electrical components are not damaged due
to a surge in the electrical supply.
When installed in a manufactured home, the appliance must
be electrically grounded to the steel chassis.
Electrical Generator Operation
Your Warmland PS45 Classic stove may be able to operate
with power from a portable generator. However, the generator’s
electrical regulator may not be compatible with the stove’s
electronics. The higher the quality of the generator, (smoother
the output sine wave) the greater the chance that it is compatible