PELLET STOVES 12 PS45 CLASSIC 151211-24
Thermostat installation
The Warmland PS45 Classic stove can be operated manually
or by a thermostat. The stove comes from the factory in the
manual mode. To operate in the two "Thermostat" modes a
low voltage thermostat must be installed. Consult dealer for
appropriate thermostat.
To install the thermostat:
1) Unplug the stove from the electrical outlet. Open the right
cabinet side (page 16, Fig #14) and remove the 2 screws holding
the main board to the side of the hopper. (see Fig. #7)
Operation
Filling the Hopper
The hopper can be accessed by lifting the hopper lid in the
top. Check for any foreign objects in the hopper before  lling
with pellets.
Control Board
The control board regulates all functions of the stove. The controls
are located on the top near the back of the unit.
2) Locate the double screw terminal wiring block at the top of
the board, (Fig. #8) loosen the two screws on the block. Insert
one of the wires from the thermostat into one of the slots and
tighten the screw. Repeat this process for the other thermostat
wire.
See Page 13 for thermostat operation modes.
IMPORTANT NOTE: Follow the Thermostat manufacturers
installation and set-up instructions. Failure to follow
manufacturers instructions could result in a malfunction. Pay
special attention to the thermostat location requirements. If
the location requirements are not followed, the appliance may
operate erratically or failure may occur.
Do not mount the thermostat where it may be affected by:
• Radiant heat from the stove, sun or other heat sources.
• Drafts or dead spots behind doors or in corners.
• Hot or cold air from ducts.
The following is a list of the board’s controls:
• POWER light - Is red during start-up, switching to green when
the stove is  nished the start-up sequence. Flashes when the
auger is feeding pellets into the Burn-Pot.
• ON/OFF Button - Is pushed to start the stove, and to turn the
auger off and start the shut down sequence.
• HEAT LEVEL Buttons - LOW is pushed to reduce the heat
output. It is also used to reduce the values of the "trim" settings.
HIGH is pushed to increase the heat output setting. It is also
used to increase the values of the "trim" settings.
AUGER TRIM - Used with the high/low buttons to trim the
auger timing pulses when the pellet quality/size requires more
or less fuel to burn properly.
• EXHAUST TRIM - Can be used with the high/low buttons to
adjust the combustion blower speed to compensate for changes
to air/fuel ratio.
• MAN-HI/LO-AUTO - Thermostat mode selector switch. The
slide switch is used to select the desired thermostat mode. (See
"Thermostat Operation" on page 13)
Thermostat
Screw Terminal
Fig. #7
Fig. #8