Thermostat Operation
Once installed, the thermostat can control the operation of the
stove. Use a low voltage/millivolt thermostat. See Page 12 for
installation instructions.
Important: When connected to a thermostat, it is necessary
to push the ignite button for the initial burn, when the electrical
ow to the stove is interrupted, or if the stove runs out of pellets
and therefore shuts off.
MANUAL Mode
After the stove is burning (see "Starting the Stove"), the heat
level setting controls the pellet feed rate and the stoves heat
output. Once set, the stove will continue to burn at this rate
until the heat level is changed or the stove is shut off.
HI/LO Mode:
After the initial ignition sequence, when the thermostat calls for
heat (the room temperature is less than the temperature set
on the thermostat), the stove will burn at the heat level setting.
The higher the setting, the quicker the room will heat up. Once
the thermostat no longer calls for heat (the room is up to the
desired temperature), the stove will drop down to burn at the
lowest HEAT LEVEL setting. This cycle will continue until the
stove is turned off or runs out of fuel.
AUTO Mode:
When the thermostat calls for heat (the room temperature is
less than the temperature set on the thermostat), the stove will
burn at the heat level setting. The higher the setting, the quicker
the room will heat up. Once the thermostat no longer calls for
heat (the room is up to the desired temperature), the stove will
drop down to burn at the lowest HEAT LEVEL setting. The stove
will continue to burn for 45 minutes at the lowest setting. If the
thermostat does not call for heat again during that time, the
stove will shut off. It will relight when the thermostat calls for
heat. If, during that 45 min., the thermostat calls for heat again,
the stove will again burn at the HEAT LEVEL setting until the
thermostat no longer calls for heat.
Paint Curing
This stove has been painted with a high temperature metallic
paint. It is dry to the touch, but completes the curing process
during the  rst few times the stove is burned. Also, some parts
of the appliance may be lightly coated with machining oil. During
the  rst  rings, the paint and oil may give off unpleasant odors.
Open the windows to ventilate the room.
Plated Surfaces
CAUTION: Always ensure that plated surfaces are clean and
free of  ngerprints before lighting stove. Fingerprints will leave
permanent blemishes if left on plated surface when hot. The door
should be gently cleaned with a soft cloth and glass cleaner.
Lighting your Stove
Note: If this is the  rst time the stove has been started or the
stove has run out of pellets, the auger will be empty and the
Burn-Pot liner will need to be primed. To prime, place a handful
of pellets into the middle of the liner.
On the control board, push the ON/OFF button. This will turn the
POWER indicator light red and will begin a 15 minute lighting
sequence. During the lighting sequence, the auger will pre-load
the Burn-Pot liner with pellets, the igniter will light the pellets and
once lit, the auger will resume feeding pellets. Some smoke inside
the  rebox can be expected during light up. Once the ignition
cycle is  nished and the stove is at operating temperature, the
POWER light will turn green. The stove will continue to burn at
the desired level indicated by the HEAT LEVEL display.
Caution: Do not attempt to re-start the lighting sequence before
it has run its course as the Burn-Pot will overload with pellets. If
after 15 minutes the stove is not lit, the middle light of the HEAT
LEVEL display will  ash red. When cooled, empty the burn pot
liner of any unburned pellets and re-start the stove.
WARNING: Never empty unburned pellets from the Burn-Pot
into the pellet hopper. Pellets that appear to be cool may retain
enough heat to ignite other pellets resulting in smoke or  re
damage.
General Operation
Use the HEAT LEVEL LOW and HIGH buttons to adjust the
heat level to the desired setting.
Avoid over  ring the stove - do not hand feed pellets to the
appliance.
Turning the Unit OFF
• Normal - To turn the stove off, press the ON/OFF button.
Lights will go out. The Auger will stop but the fans and Burn-Pot
Cleaner will continue to operate until the temperature drops and
the control board completes the shut down cycle.
• Power Outage - If the stove loses electrical power and it is hot
when power returns, the stove will go into a start-up sequence
and will continue to operate. If the power loss is long enough
for the stove to cool, the stove will not start until the ON/OFF
switch is pressed. If the stove is connected to a thermostat in
the Auto mode", the stove will not start the ignition sequence
until the thermostat calls for heat again.
Convection Blower Operation
Your Warmland PS45 Classic stove comes equipped with a
convection blower that extracts heat from the stove. After the
stove warms up, the fan will turn on. The speed of the fan varies
with the burn rate of the stove. The fan will continue to extract
heat after the stove shuts off and until it has cooled down.
Operating Sounds
As the Warmland PS45 Classic stove is burning, a number of
normal operational sounds may be heard. When the blowers
come on, the sound of rushing air can be heard. The lower the
burn rate the slower the fan operates. Pellets can be heard
dropping into the Burn-Pot. Also, the motors turning the auger
and the Burn Pot Mixer may be heard as they pulse on and
off. Occasionally a noise might be heard as the auger cuts a
pellet in half.